Inspection of a printed circuit board.
PHOENIX / GE PCBA Analyser 160
Technical Data:
|
Micro-focus-tube |
|
Power: |
160 KV |
|
Operating range: | 10 to 160 KV | |
Steps: | 1 mA / 20 W | |
Focal spot: | 3 µW | |
Working area: | 650 x 550 mm | |
|
750 x 750 mm | |
Image intensifier: | digital & analog | |
Dig. image intensifier: | up to 45° tiltable | |
Manipulator: | 5-axis control |
High resolution semi automatic X-Ray scanner. Imaging is fully digital, the component can be moved in 5 degrees of freedom via CNC.
Scanner and Testing Chamber are certified as specified in the TÜV X-Ray regulations.
Various components we can test for in our X-Ray scanning lab!
Weld joints of pipes up to a diameter of 90 mm are tested using ellipse scanning.
Two shots at 0° + 90°. According to DIN EN ISO 17636-2, 7.1.6, Picture 11.
Preparing the X-ray-test of a carbon fiber aluminum composite part
Carbon aluminum composite, size of the hexagons is just 5 mm!
Illustration